Automation

AGRICULTURE

FEEDER SOLUTIONS
SINGLE AUGER FEEDER

SINGLE AUGER FEEDER 2B SINGLE AUGER FEEDER 2B

FUNCTIONALITY
  • Providing feed to feeders from the silo with minimal human intervention.
  • The Single Auger Feeder controls one auger (55mm or 75mm) that provides feed to a single line of feeders from the silo.
SYSTEM SPECIFICATION
  • Manual and Automatic control of auger motor.
  • Option of an end of line proximity to automatically stop and restart the auger motor to keep feeders full.
  • Door switch enables the bypass of the Feeder proximities if the need arise.
  • Option to choose between Feeder proximity 1 or 2.
  • Incorporates flap limit switch as extra protection to stop the auger motor and prevent damage to the motor and auger.
  • Green and red lights to indicate Auger status.
  • Emergency stop as safety measure to immediately stop the whole feeding system.
System Motor Rating and Application

0.75kW for a 55mm Auger
1.1kW for a 75mm Auger

Order By Email

Item Code: SAF2B or SAF3A

DOUBLE AUGER FEEDER

DOUBLE AUGER FEEDER DOUBLE AUGER FEEDER

FUNCTIONALITY
  • Providing feed to feeders from the silo with minimal human intervention.
  • The Double Auger Feeder controls two augers (55mm or 75mm) that provide feed to a double line of feeders from the silo.
SYSTEM SPECIFICATION
  • Manual and automatic control of auger 1 and auger 2 motor.
  • Option of an end of line proximity to automatically stop and restart the auger 1 or 2 motor to keep feeders full.
  • Door switch enables the bypass of the Feeder proximities if the need arise.
  • Option to choose between Feeder proximity 1 or 2 for each auger feeder.
  • Incorporates flap limit switch as extra protection to stop the auger 1 and auger 2 motor and prevent damage to the motors and augers.
  • Green and red lights to indicate Auger status.
  • Emergency stop as safety measure to immediately stop the whole feeding system.
System Motor Rating and Application

0.75kW for a 55mm Auger
1.1kW for a 75mm Auger

Order By Email

Item Code: DAF2B or DAF3A

TRIPLE AUGER FEEDER

TRIPLE AUGER FEEDER TRIPLE AUGER FEEDER

FUNCTIONALITY
  • Providing feed to feeders from the silo with minimal human intervention.
  • The Triple Auger Feeder controls three augers (55mm or 75mm) that provide feed to a three line of feeders from the silo.
SYSTEM SPECIFICATION
  • Manual and Automatic control of auger motor.
  • Option of an end of line proximity to automatically stop and restart the auger 1, 2 and 3 motor to keep feeders full.
  • Door switch enables the bypass of the Feeder proximities if the need arise.
  • Option to choose between Feeder proximity 1 or 2 for each auger feeder.
  • Incorporates flap limit switch as extra protection to stop the auger motor and prevent damage to the motor and auger.
  • Green and red lights to indicate Auger status.
  • Emergency stop as safety measure to immediately stop the whole feeding system.
System Motor Rating and Application

0.75kW for a 55mm Auger
1.1kW for a 75mm Auger

How To Order By Email

Item Code: TAF2B or TAF3A

SINGLE CHAIN & DISK FEEDER

SINGLE CHAIN AND DISK FEEDER SINGLE CHAIN AND DISK FEEDER

FUNCTIONALITY
  • Providing feed to feeders from the silo with minimal human intervention.
  • It uses the chain to distribute the feed is small quantities.
  • The Chain&Disk supply feed via routable Chain&Disk line that can fill more than one line of feeders.
SYSTEM SPECIFICATION
  • Manual and Automatic control of auger motor.
  • Option of an end of line proximity to automatically stop and restart the auger motor to keep feeders full.
  • Door switch enables the bypass of the line end proximity if the need arise.
  • Option to choose between Feeder proximity 1 or 2 of auger 1.
  • Incorporates tension and LID limit switch as extra protection for auger motor and as safety precaution respectively.
  • Green and red lights to indicate Auger status.
  • Emergency stop as safety measure to immediately stop the whole feeding system.
System Motor Rating and Application

1.5kW for a 55mm Auger

Order By Email

Item Code: SCD2B

SINGLE CHAIN & DISK FEEDER WITH AUTOFEED

SINGLE CHAIN AND DISK FEEDER WITH AUTOFEED SINGLE CHAIN AND DISK FEEDER WITH AUTOFEED

FUNCTIONALITY
  • Providing feed to feeders from the silo with minimal human intervention.
  • It uses the chain to distribute the feed is small quantities.
  • The Chain&Disk supply feed via routable Chain&Disk line that can fill more than one line of feeders.
  • Programmable daily multiple feed routine, opening feeders with winch.
SYSTEM SPECIFICATION
  • Manual and Automatic control of auger motor.
  • Option of an end of line proximity to automatically stop and restart the auger motor to keep feeders full.
  • Door switch enables the bypass of the line end proximity if the need arise.
  • Incorporates tension and lid limit switch as extra protection for auger motor and as safety precaution respectively.
  • Green and red lights to indicate Auger status.
  • Emergency stop as safety measure to immediately stop the whole feeding system.
System Motor Rating and Application

1.5kW for a 55mm Auger
0.185kW for Winch operation

Order By Email

Item Code: SCD-WAF

DOUBLE CROSSOVER FEEDER

DOUBLE CROSSOVER FEEDER DOUBLE CROSSOVER FEEDER

FUNCTIONALITY
  • Providing feed to feeders from the silo with minimal human intervention.
  • The Double Cross-over Feeder uses the auger to supply feed from the silo, with overthrow to the Chain&Disk and the Chain&Disk supply feed via routable Chain&Disk line that can fill more than one line of feeders.
SYSTEM SPECIFICATION
  • Manual and Automatic control of auger motor.
  • Option of an end of line proximity to automatically stop and restart the auger motor to keep feeders full.
  • Door switch enables the bypass of the Feeder proximities if the need arise.
  • Option to choose between Feeder proximity 1 or 2.
  • Incorporates flap limit switch as extra protection to stop the auger motor and prevent damage to the motor and auger.
  • Green and red lights to indicate Auger status.
  • Emergency stop as safety measure to immediately stop the whole feeding system.
System Motor Rating and Application

1.1kW for a 55mm Chain & Disk
0.75kW for a 55mm Auger

Order By Email

Item Code: DCF3A

MISPUT 5

MISPUT5 MISPUT5

FUNCTIONALITY
  • Mixer agitate manure and water mixture to prevent settling.
  • Pump pumps the manure mixture out.
SYSTEM SPECIFICATION
  • Auto settings automatically activate and stop stirrer (and after a set period) the pump, depending on the level of manure in the manure pit.
  • Manual control of pump and stirrer individually.(NB: pump and stirrer does not switch off automatically in this condition and pump can run dry and sustain damage.)
  • Green and red trip light to indicate Stirrer and Pump status.
  • Emergency stop in case of emergencies, to immediately stop the stirrer and pump.
System Motor Rating and Application

2.2kW for a Stirrer
2.2kW for a Pump

Order By Email

Item Code:MS-05

MISPUT 5A

MISPUT5A MISPUT5A

FUNCTIONALITY
  • Mixer agitate manure and water mixture to prevent settling.
  • Pump pumps the manure mixture out.
SYSTEM SPECIFICATION
  • Auto settings automatically activate and stop stirrer (and after a set period) the pump, depending on the level of manure in the manure pit.
  • Manual control of pump and stirrer individually.(NB: pump and stirrer does not switch off automatically in this condition and pump can run dry and sustain damage.)
  • Pump 2 is controlled with pump 1 or separate from pump 1.
  • Green and red trip light to indicate Stirrer and Pump status.
  • Emergency stop in case of emergencies, to immediately stop the stirrer and pump.
System Motor Rating and Application

2.2kW for a Stirrer
2.2kW for a Pump

Order By Email

Item Code:MS-5A

VENTILATION 12

FUNCTIONALITY
  • It controls three groups of ventilation fans.
  • Fan group 1 requires analog signal to set fan group 1 speed. Fan group 2 and 3 is D.O.L (Direct on Line).
  • " The ventilation regulates the air flow and cooling to maintain a set room temperature under command of an external control system or under manual control.
SYSTEM SPECIFICATION
  • Manual control activates each of three fan groups.
  • Individual fan on/off control to eliminate any given fan adding flexibility.
  • Automatic control accepts external control for total ventilation per group. Variable speed control of fan group 1 allows almost infinite precision of air flow in combination with fan group 2 and 3.
  • Green and red light to indicate fan status.
  • Manual control of water pump activates pump manually for cooling.
  • Automatic control of water pump accepts external control to control cooling.
  • External inputs: 24VDC.
  • Analog signal for fan group 1: 0-10VDC
System Motor Rating and Application

0.51-1.1kW for the fans
2.2kW for a Water Pump
2.2kW for Cooling Motor

Order By Email

Item Code:VFC-4/6/8/12

HEATER FAN 9

FUNCTIONALITY
  • It regulates the heater fans that heat the house.
  • Each heater fan group controls half of the heater fans. The second heater fan group can be set to activate with an adjustable delay in order to minimise power consumption while achieving control goals.
SYSTEM SPECIFICATION
  • Manual operation activates all fans by hand for each of two groups.
  • Automatic control accepts 220V external control to activate heater fans.
  • Individual heater fan on/off control to eliminate any given fan.
  • Green and red light to indicate heater fan status.
  • Manual control of water pump activates pump manually for cooling.
  • Automatic control of water pump accepts external control to control cooling.
System Motor Rating and Application

0.51kW for the fans
9kW for a Heater fans

Order By Email

Item Code:HFC-2/4/6/9

FARROW HEATER

FUNCTIONALITY
  • Controls heater lights and heater pads for the farrowing house
SYSTEM SPECIFICATION
  • Manual and automatic control capabilities.
  • Green light to indicate the status of the controlled lights.
  • Optional External Lights and Heater Lights Controller.
  • 24 hour timer to automatically switch on and off the lights for the farrowing house.
  • 17 Heater pads per row at 150W (NB. The number of heaterpads depends on the size of the farrowing or weaner house).
  • 17 Heater lights per row at 175W (NB. The number of heaterlights depends on the size of the farrowing or weaner house).
System Motor Rating and Application

1 Row of Slats
2 Rows of Slats
3 Rows of Slats

Order By Email

Item Code:FH-1/2/3
Item Code:WH-1/2/3

FARROW CLIMATE CONTROL

FUNCTIONALITY
  • Controls heater lights and heater pads for the farrowing house.
SYSTEM SPECIFICATION
  • Manual and automatic control capabilities.
  • Green light to indicate the status of the controlled lights and pads.
  • VSD for fan speed control.
  • Pump and lighting control capability.
  • Alarm and strobe light indication.
  • Temperature controller.
  • 54 Heater pads per row at 150W (NB. The number of heaterpads depends on the size of the farrowing or weaner house).
  • 54 Heater lights per row at 175W (NB. The number of heaterlights depends on the size of the farrowing or weaner house).
System Motor Rating and Application

0.51kW for the fans
9kW for a Heater fans

Order By Email

Item Code:FCC-2

WIRELESS ALARM BOX AND BACKUP POWER SUPPLY

FUNCTIONALITY
  • It processes and make alarm in the area in which it is installed through SMS notification and audible alarm.
SYSTEM SPECIFICATION
  • Multiple applications of use.
  • Antenna for wireless communication.
  • Dual sim card slot.
  • Backup power supply unit in case of power shortages.
  • Relay 1 and 2 accepts 24V DC supply signal for Zone 1 and Zone 2 to be activated respectively.
  • Relay 3 requires constant 220V AC signal, if the signal is not received, Zone 3 alarm will be activated.
  • Relay 4 requires 220V AC signal for Zone 4 to be activated
  • Bypass and On switch to enable or disable an alarm zone.
  • Siren to make alarm and can be enabled and disabled.
  • SMS notification of specific area of alarm.
System Motor Rating and Application

Alarm trigger switches or sensors in monitored zones.

Order By Email

Item Code:WA-01Item Code:BPS-01

GREEN HOUSE

FUNCTIONALITY
  • It controls all the process valves and actuators.
SYSTEM SPECIFICATION
  • Manual and auto capabilities.
  • Interfacing with PLC control.
  • Run and trip signals for process monitoring.
System Motor Rating and Application

7.5kW for the fans
2.2kW for a water pumps
0.75kW for a mist pumps
0.42kW for a ventilation window

Order By Email

Item Code:WA-01Item Code:GHC-01